Opis
Kompletny zestaw pomiarowy PSK (YII i Fv/Fm) składający się z:
- ręczny fluorymetr ze światłem modulowanym (OSI-YII-MTR) do pomiaru Y(II), ETR, PAR, temperatury liścia, RH, absorpcyjności i transmitancji liścia,
- ręczny fluorymetr do pomiarów w zaciemnieniu Fv/Fm, Fv/Fo, Fo, Fv i Fm (OSI-FV-MTR).
W zestawie 2 baterie, 10 klipsów do zaciemniania liścia, uniwersalna ładowarka, walizka transportowa, 2 karty kalibracyjne i dokumentacja zapisana na pendrivie.
PSK Plant Stress Kit
Includes the Y(II) meter and the FV/FM meter
Y(II) meter
Measures light adapted Y(II) protocol with an FM’ correction option, PAR, ETR, Leaf temp, & Leaf absorptance
The Y(II) meter was designed to provide an inexpensive way to measure the fast light adapted Y(II) or ΔF/FM’ protocol and to make it available to more people that need it.
Opti-Sciences developed a system that does not require expensive fiber optics, but still follows the proven methods needed for reliable plant stress measurement. Y(II) is measured from the top of the leaf along with PAR or photosynthetically active radiation. Furthermore, leaf temperature is measured from the bottom over a large area, allowing a more reliable value.
Measures the light adapted Y(II) protocol with an FM’ correction option, PAR, ETR, Leaf temp, & Leaf absorptance.
Features:
- The Y(II) meter may be purchased separately from the Plant Stress Kit
- Y(II) measurement & ETR measurement can be corrected for leaf absorptance
- Leaf absorptance measurement including leaf transmittance using RGB sensors
- PAR measurement
- Non Contact Leaf temperature measurement averaged over a large area
- FM’ correction option at high actinic light levels, according to Loriaux 2013
- Diurnal monitoring capability designed for growth chamber work. It allows measurement day and night. Useful for laboratory work.
- Relative humidity sensor
- USB transfer of comma delineated files to Excel ® or other spread sheets.
FV/FM meter
Modulated fluorometer measures FV/FM
FV/FM meter was designed to offer an inexpensive companion instrument to the Y(II) meter to allow measurement of the dark adaptated FV/FM protocol.
Features:
- Works with inexpensive dark clips to allow measurement of large populations quickly.
- Graphic FV/FM trace display
- 2 GB of memory allow storage of tens of thousands of measurements
- USB transfer of comma delineated files to Excel ® or other spread sheets.
Y(II) Meter Specifications:
Fast measurements:
Y(II) or ΔF/FM’ with the option for FM’ correction according to Loriaux 2013 included. ETR, PAR, leaf temperature, relative humidity, leaf absorptance, FS, FM’ and FT.
Monitor mode:
Measures the same sample for months at a time, using a USB battery pack or mains current. The monitor is designed for growth chamber, or laboratory work but not field work. The instrument can be programmed to measure at different intervals during light and dark periods. The monitor mode allows measurement of Y(II) or ΔF/FM’, ETR, PAR, leaf temperature, relative humidity and leaf absorptance. From the dark period data, FV/FM, NPQ, Y(NPQ), and Y(NO) can be calculated.
Lighting conditions:
Ambient light only at steady state photosynthesis.
Light sources:
White LED saturation flash to 7,000 μmoles.
Choice of red modulated light source (660nm with 690nm cut off filter), or blue modulated light source (450nm) at time of purchase.
Sensors:
2 RGB sensors for measurement of leaf reflectance, leaf transmittance, and leaf absorptance, calibrated with standard. From 0 to 100%.
PAR sensor measures from 400nm to 700nm, cosine corrected. +- 2 μmols
Pin Photodiode with a 700nm to 750nm band pass filter.
Relative humidity 0% to 100% +-2%
Power:
Lithium-ion USB battery pack with 8 hour life. Designed to be carried in a pocket. The unit may be used with any USB compatible battery. The instrument will also run on most mains current USB chargers.
Size:
17 x 4 x 5 cm
USB cable 81 cm long
Battery 12 x 2.5 x 2.5 cm
Weight with battery 0.36 kg
Memory:
2 Gigabytes
Output:
Standard USB storage device. Comma delineated files. Files may be opened in Excel or other programs with spread sheet formats.
Graphic screen display:
132 X by 30 pixel LCD.
FV/FM Meter Specifications:
Fast measurements:
FV/FM , FV/FO, FO, & FM.
Light source:
Array of red LEDs at 660 nm.
Lighting conditions:
Dark adapted conditions only.
Light sources:
Red LED Saturation flash array up to 6,000 μmoles.
Red modulated light source (660nm with a 690nm cut off filter).
Sensors:
Pin Photodiode with a 700nm to 750nm band pass filter.
Power:
Lithium-ion USB battery pack with 8 hour life. Designed to be carried in a pocket. The unit may be used with any USB compatible battery. The instrument will also run on most mains current USB chargers.
Size:
22 x 3 x 4 cm
USB cable 81 cm long
Battery 4.5″ x 1″ x 1″ (12 x 2.54 x 2.54 cm)
Weight with battery 0.8 lbs (0.36 kg)
Memory:
2 Gigabytes
Output:
Standard USB storage device. Comma delineated files. Files may be opened in Excel or other programs with spread sheet formats.
Graphic screen display:
132 X by 30 pixel LCD.